EU Standard DC

Products

EU/US Standard DC Single Gun Main Control Board

European/American Standard DC Single-Gun Mainboard - Image 1

Product Overview

SDEE-DC-OB1CC is the main control board for our self-developed DC charging series, primarily designed for Euro-standard single-gun DC chargers and US-standard single-gun DC chargers. It is suitable for wall-mounted small DC units, floor-standing integrated stations, or charging stacks.

The hardware supports integrated Ethernet, 4G, Bluetooth, and Wi-Fi modules, with seamless on-screen switching between connectivity options.

Built-in OCPP1.6J communication protocol, scalable to OCPP2.0; supports Tuya and overseas connection to the master control board maintenance platform.

Supports multiple screen sizes (typical: 4.3/7/10/13 inches), multi-language display, and UI customization.

Supports multiple charging methods: EVCCID (MAC), card swipe (POS compatible), password entry, and QR code scanning.

Supports EMS integration, power limiting, diagnostic log polling, and OTA updates (via operations platform, maintenance platform, or charge point screen).

Connected to major international platforms (PEA, PLN, LMS, MONTA). Our charging stations have obtained OCA certification and TUV certification in collaboration with customers.

Specifications

Power30kW~480kW
Input Voltage12V
Input Current≥2A
Card Reader Interface1-port 232 interface supports first-card readers/POS terminals
Display Interface1-channel 232 interface supports 5V/12V power output
Indicator LED Interface2 group drivers: support constant-on, running light, and SOC light
DI digital input interface5-channel input interface, active
DO has been issued with an interface.4-port passive interface
CC1 Sampling Interface1-channel CC1 analog sampling interface (for national standard charging guns)
Electronic Lock Control Interface1-channel pulse drive, supports power-loss unlocking (GB standard connector only)
Gun temperature sampling interface2 channels support PT1000 sensors for real-time charging gun temperature monitoring.
Electric meter communication interface1 485 ports supporting DL/T645-2007 protocol and MID-compliant meters
Insulation Monitoring Module Communication Interface1-channel 485 interface
Reserve 485 communication interface1 lanes, supporting EMS integration or liquid-cooled supercharging gun connection
Debug Interface1-port 232 interface; supports logging and main control board parameter modification
Network Communication InterfaceEthernet standard; 4G/Bluetooth/Wi-Fi optional
Onboard CAN interface2 CAN interfaces, connected to the power module and BMS/SECC respectively
Operating Temperature-40°C ~ 85°C
Storage Temperature-20°C ~ 65°C

Need a custom solution?

We offer custom PCBA solutions tailored to your needs, from schematic design to mass production delivery.